Instrument
Noise transmission
route
When measuring instruments, receivers, sensors, etc. which handle weak signals and may
malfunction due to noise and/or their signal cables are contained in a control box together with the
servo amplifier or run near the servo amplifier, such devices may malfunction due to noises
transmitted through the air. The following techniques are required.
1. Provide maximum clearance between easily affected devices and the servo amplifier.
1) 2) 3)
2. Provide maximum clearance between easily affected signal cables and the I/O cables of the servo
3. Avoid laying the power lines (Input cables of the servo amplifier) and signal cables side by side or
4. Insert a line noise filter to the I/O cables or a radio noise filter on the input line.
5. Use shielded wires for signal and power cables or put cables in separate metal conduits.
When the power lines and the signal cables are laid side by side or bundled together, magnetic
induction noise and static induction noise will be transmitted through the signal cables and malfunction
may occur. The following techniques are required.
1. Provide maximum clearance between easily affected devices and the servo amplifier.
4) 5) 6)
2. Provide maximum clearance between easily affected signal cables and the I/O cables of the servo
amplifier.
3. Avoid laying the power lines (I/O cables of the servo amplifier) and signal cables side by side or
bundling them together.
4. Use shielded wires for signal and power cables or put the cables in separate metal conduits.
When the power supply of peripheral devices is connected to the power supply of the servo amplifier
system, noises produced by the servo amplifier may be transmitted back through the power supply
7)
cable and the devices may malfunction. The following techniques are required.
1. Insert the radio noise filter (FR-BIF) on the power cables (Input cables) of the servo amplifier.
2. Insert the line noise filter (FR-BSF01) on the power cables of the servo amplifier.
When the cables of peripheral devices are connected to the servo amplifier to make a closed loop
8)
circuit, leakage current may flow to malfunction the peripheral devices. If so, malfunction may be
prevented by disconnecting the grounding cable of the peripheral device.
7)
Receiver
amplifier.
bundling them together.
5)
7)
2)
1)
Servo
amplifier
3)
6)
4)
Servo motor
M
Suppression techniques
11 - 35
7)
Sensor
power supply
2)
8)
Sensor
3)