5. DISPLAY AND OPERATION SECTIONS
5.6.3 Operation example
(1) Setting of 3 or less digits
The following example shows the operation procedure performed after power-on to set the auxiliary
function of the point table No.1 to "1".
To the next setting
After setting (1), to shift to other items of the same point table No., press the "UP" or the "DOWN" button.
To shift to the next point table No., press the "MODE" button.
POINT
When the set value of a specified point table is changed and entered, the
entered set value is displayed. The set value can be cancelled by pressing
the "MODE" button for 2[s] or longer immediately after entering the value.
Then, the previous set value is displayed.
Press MODE three times.
The point table No. is displayed.
Press UP or DOWN to choose the point table No.1.
Press SET once.
Press UP five times.
Press SET twice.
The set value of the specified point table No. blinks.
Press UP once.
During blinking, the set value can be changed.
Set with UP or DOWN.
Press SET to enter.
5 - 15