Servo Amplifier Terminal Block (Te2) Wiring Method; For Servo Amplifier Produced Later Than January, 2006 - Mitsubishi Electric MR-J2S B Series Instruction Manual

Servo amplifier
Table of Contents

Advertisement

3. SIGNALS AND WIRING

3.9 Servo amplifier terminal block (TE2) wiring method

3.9.1 For servo amplifier produced later than January, 2006

(1) Termination of the cables
(a) Solid wire
After the sheath has been stripped, the cable can be used as it is.
(b) Twisted wire
1) When the cable is inserted directly
Use the cable after stripping the sheath and twisting the core. At this time, take care to avoid a
short caused by the loose wires of the core and the adjacent pole. Do not solder the core as it may
cause a contact fault.
2) When the twisted wires are put together using a bar terminal
Use the bar terminal shown below.
Cable Size
2
[mm
]
1.25/1.5
2/2.5
Cut the cable running out of bar terminal to less than 0.5 mm
When using a bar terminal for 2 cables, insert the cables in the direction where the insulation sleeve
does not interfere with next pole, and pressure then.
POINT
Refer to table 12.1 2) and (4) of section 12.2.1 for the wire sizes used for
wiring.
Bar Terminal Type
AWG
For 1 cable
16
AI1.5-10BK
14
AI2.5-10BU
Sheath
Core
Approx. 10mm
For 2 cables
AI-TWIN2
1.5-10BK
Less than 0.5mm
Pressure
Pressure
3 - 27
Crimping Tool
Manufacturer
CRIMPFOX ZA 3
Phoenix Contact