Mitsubishi Electric MELSERVO-JN Series Instruction Manual page 100

General-purpose ac servo, general purpose interface servo amplifier/motor
Table of Contents

Advertisement

4. PARAMETERS
4.1.2 Parameter write inhibit
No.
Symbol
PA19
*BLK
Parameter write inhibit
In the factory setting, this servo amplifier allows to change all the setting parameters. With the setting of
parameter No. PA19, writing can be disabled to prevent accidental changes.
The following table indicates the parameters which are enabled for reference and writing by the setting of
parameter No. PA19. Operation can be performed for the parameters marked
Parameter No. PA19
setting
operation
Reference
000h
Reference
00Ah
Reference
00Bh
Reference
00Ch
00Eh
Reference
(initial value)
Reference
10Bh
Reference
10Ch
Reference
10Eh
Parameter
Name
POINT
This parameter is made valid when power is switched off, then on after setting.
Basic setting
Setting
parameters
No. PA
Writing
Parameter No.
PA19 only
Parameter No.
Writing
PA19 only
Writing
Writing
Writing
Parameter No.
Writing
PA19 only
Parameter No.
Writing
PA19 only
Parameter No.
Writing
PA19 only
Initial
value
00Eh
Gain/Filter
Extension setting
parameters
parameters
No. PB
No. PC
4 - 3
Control mode
Setting
Unit
range
Position
Refer to
the text.
.
I/O setting
parameters
No. PD
Internal
Internal
speed
torque
Positioning
setting
parameters
No. PE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-jn-10aMr-jn-20a1Mr-jn-20aMr-jn-40aMr-jn-10a1