3. SIGNALS AND WIRING

3.2.2 Internal speed control mode

(Note 3, 5)
Forced stop
Servo-on
(Note 9,
Reset
10, 12)
Speed selection 1
Forward rotation
start
Reverse rotation
start
Personal
(Note 8)
computer
MR Configurator
Note 1. To prevent an electric shock, always connect the protective earth (PE) terminal (terminal marked
main circuit power connector (CNP1) to the protective earth (PE) of the control box.
2. Connect the diode in the correct direction. If it is connected reversely, the servo amplifier will be faulty and will not output
signals, disabling the emergency stop and other protective circuits.
3. The forced stop switch (normally closed contact) must be installed.
4. Supply 24VDC 10% 200mA current for interfaces from the outside. 200mA is the value applicable when all I/O signals are used.
The current capacity can be decreased by reducing the number of I/O points. Refer to section 3.8.2 (1) that gives the current
value necessary for the interface.
5. When starting operation, always switch on the forced stop (EM1). (Normally closed contacts)
6. Trouble (ALM) turns on in normal alarm-free condition. (Normally closed contact)
7. The pins with the same signal name are connected in the servo amplifier.
8. Use MRZJW3-SETUP221E (C4 or later).
9. This diagram shows sink I/O interface. For source I/O interface, refer to section 3.8.3.
10. The assigned signals can be changed using the settings of parameter No. PD02 to PD14.
11. The assigned signals can be changed using the settings of parameter No. PD15 to PD18.
12. The forward rotation stroke end (LSP) and the reverse rotation stroke end (LSN) automatically switch ON if not assigned to the
external input signals.
(Note 4, 9)
24VDC
DICOM
DOCOM
EM1
SON
RES
SP1
ST1
ST2
10m max.
USB cable
(option)
3 - 6
Servo amplifier
(Note 7)
(Note 7)
(Note 2)
CN1
CN1
1
9
ALM
13
10
SA
8
4
11
RD
3
12
MBR
5
6
7
19
LZ
20
LZR
15
LA
CN3
16
LAR
17
LB
18
LBR
14
LG
21
OP
SD
Plate
2m max.
CNP1
(Note 1)
Trouble (Note 6)
RA1
Speed reached
RA2
Ready
RA3
Electromagnetic
RA4
brake interlock
10m max.
Encoder Z-phase pulse
(differential line driver)
Encoder A-phase pulse
(differential line driver)
Encoder B-phase pulse
(differential line driver)
Control common
Control common
Encoder Z-phase pulse
(open collector)
) of the servo amplifier
(Note 9, 11)