App. 5.1.4 General cautions for safety protection and protective measures
Observe the following items to ensure proper use of the MELSERVO MR-JN servo amplifiers.
(1) Only qualified personnel and professional engineers should perform system installation.
(2) When mounting, installing, and using the MELSERVO MR-JN servo amplifier, always observe applicable
standards and directives in the country.
App. 5.1.5 Disposal
Disposal of unusable or irreparable devices should always occur in accordance with the applicable country-
specific waste disposal regulations. (Example: European Waste 16 02 14)
App. 5.2 Mounting/dismounting
Installation direction and clearances
CAUTION
The devices must be installed in the specified direction. Not doing so may cause
a malfunction.
Mount the servo amplifier on a cabinet which meets IP54 in the correct vertical
direction to maintain pollution degree 2.
10 mm
or more
Cabinet
Top
40 mm
or more
10 mm
or more
40 mm
or more
Bottom
App. - 14
Cabinet
80 mm or longer
for wiring
Servo amplifier