Danfoss VLT AutomationDrive FC 300 Programming Manual page 44

Hide thumbs Also See for VLT AutomationDrive FC 300:
Table of Contents

Advertisement

FC 300 Programming Guide
0-51 Set-up Copy
Option:
[0] *
No copy
[1]
Copy to set-up 1
[2]
Copy to set-up 2
[3]
Copy to set-up 3
[4]
Copy to set-up 4
[9]
Copy to all
3.2.8 0-6* Password
Define password access to menus.
0-60 Main Menu Password
Range:
100 N/A*
[0 - 999 N/A]
0-61 Access to Main Menu w/o Password
Option:
[0] *
Full access
[1]
LCP: Read only
[2]
LCP: No access
[3]
Bus: Read only
[4]
Bus: No access
[5]
All: Read only
[6]
All: No access
If
Full access
[0] is selected then par. 0-60
Password
will be ignored.
0-65 Quick Menu Password
Range:
200*
[-9999 - 9999 ]
Function:
No function
Copies all parameters in the present Programming Set-up (defined in par. 0-11
up
) to Set-up 1.
Copies all parameters in the present Programming Set-up (defined in par. 0-11
up
) to Set-up 2.
Copies all parameters in the present Programming Set-up (defined in par. 0-11
up
) to Set-up 3.
Copies all parameters in the present Programming Set-up (defined in par. 0-11
up
) to Set-up 4.
Copies the parameters in the present set-up over to each of the set-ups 1 to 4.
Function:
Define the password for access to the Main Menu via the [Main Menu] key. If par. 0-61
Main Menu w/o Password
is set to
Function:
Disables password defined in par. 0-60
Prevent unauthorized editing of Main Menu parameters.
Prevent unauthorized viewing and editing of Main Menu parameters.
Read-only functions for parameters on fieldbus and/or FC standard bus.
No access to parameters is allowed via fieldbus and/or FC standard bus.
Read-only function for parameters on LCP, fieldbus or FC standard bus.
No access from LCP, fieldbus or FC standard bus is allowed.
Main Menu Password
, par. 0-65
Personal Menu Password
Function:
Define the password for access to the Quick Menu via the [Quick Menu] key. If par. 0-66
Quick Menu w/o Password
is set to
®
MG.33.M8.02 - VLT
is a registered Danfoss trademark
3 Parameter descriptions
Full access
[0], this parameter will be ignored.
Main Menu Password
.
and par. 0-66
Access to Personal Menu w/o
Full access
[0], this parameter will be ignored.
Programming Set-
Programming Set-
3
Programming Set-
Programming Set-
Access to
Access to
43

Advertisement

Table of Contents
loading

Table of Contents