Danfoss VLT AutomationDrive FC 300 Programming Manual page 171

Hide thumbs Also See for VLT AutomationDrive FC 300:
Table of Contents

Advertisement

3 Parameter descriptions
12-09 Physical Address
Range:
[00:1B:08:00:00:00 – 00:1B:
08:FF:FF:FF]
3.13.2 12-1* Ethernet Link Parameters
3
12-1* Ethernet Link Parameters
Option:
[0]
Port 1
[1]
Port 2
12-10 Link Status
Option:
[0]
No link
[1]
Link
12-11 Link Duration
Option:
Link Duration Port 1 (dd:hh:mm:ss) Read only. Displays the duration of the present link on each port in dd:hh:mm:ss.
12-12 Auto Negotiation
Option:
[0]
Off
[1]
On
12-13 Link Speed
Option:
[0] *
None
[1]
10 Mbps
[2]
100 Mbps
12-14 Link Duplex
Option:
[0]
Half duplex
[1] *
Full duplex
3.13.3 12-2* Process Data
12-20 Control Instance
Range:
[None, 20, 21, 100, 101, 103]
170
Function:
Read only Displays the Physical (MAC) address of the option.
Function:
Applies for whole parameter group.
Function:
Read only. Displays the link status of the Ethernet ports.
Function:
Function:
Configures Auto Negotiation of Ethernet link parameters, for each port: ON or OFF.
Link Speed
and
Link Duplex
can be configured in par. 12-13 and 12-14.
Function:
Forces the link speed for each port in 10 or 100 Mbps. If par. 12-12 is set to: ON, this parameter is
read only and displays the actual link speed. "None" is displayed if no link is present.
Function:
Forces the duplex for each port to Full or Half duplex. If par. 12-12 is set to: ON, this parameter is
read only.
Function:
Read only. Displays the originator-to-target connection point. If no CIP connection is present "None"
is displayed.
®
MG.33.M8.02 - VLT
is a registered Danfoss trademark
FC 300 Programming Guide

Advertisement

Table of Contents
loading