3 Parameter descriptions
For additional guidelines in the selection of
the installed fieldbus.
Option:
[0] *
FC profile
[1]
PROFIdrive profile
[5]
ODVA
[7]
CANopen DSP 402
3
[8]
MCO
8-13 Configurable Status Word STW
Option:
[0]
No function
[1] *
Profile Default
[2]
Alarm 68 Only
[3]
Trip excl Alarm 68
[10]
T18 DI status.
[11]
T19 DI status.
[12]
T27 DI status.
[13]
T29 DI status.
[14]
T32 DI status.
[15]
T33 DI status.
[16]
T37 DI status
[21]
Thermal warning
[30]
Brake fault (IGBT)
[40]
Out of ref range
[60]
Comparator 0
[61]
Comparator 1
[62]
Comparator 2
[63]
Comparator 3
[64]
Comparator 4
[65]
Comparator 5
[70]
Logic Rule 0
[71]
Logic Rule 1
[72]
Logic Rule 2
[73]
Logic Rule 3
[74]
Logic Rule 4
[75]
Logic Rule 5
[80]
SL Digital Output A
[81]
SL Digital Output B
[82]
SL Digital Output C
138
PROFIdrive profile
ODVA
[1],
[5] and
Function:
Function:
This parameter enables configuration of bits 12 – 15 in the status word.
The input is always low.
Depended on the profile set in Parameter 8-10.
The input will go high whenever Alarm 68 is active and will go low whenever no alarm 68 is active
The input will go high whenever Trip on other Alarms then Alarm 68 is active.
The input will go high whenever T18 has 24V and will go low whenever T18 has 0V
The input will go high whenever T19 has 24V and will go low whenever T19 has 0V
The input will go high whenever T27 has 24V and will go low whenever T27 has 0V
The input will go high whenever T29 has 24V and will go low whenever T29 has 0V
The input will go high whenever T32 has 24V and will go low whenever T32 has 0V
The input will go high whenever T33 has 24V and will go low whenever T33 has 0V
The input will go high whenever T37 has 0V and will go low whenever T37 has 24V
The thermal warning turns on when the temperature exceeds the limit in the motor, the frequency
converter, the brake resistor, or the thermistor..
Will go high when the brake IGBT is short-circuited.
If Comparator 0 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Comparator 0 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Comparator 1 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Comparator 2 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Comparator 3 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Comparator 4 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Comparator 5 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Logic Rule 0 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Logic Rule 1 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Logic Rule 2 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Logic Rule 3 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Logic Rule 4 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
If Logic Rule 5 is evaluated as TRUE, the input will go high. Otherwise, it will be low.
SL Controller Action. The input will go high whenever the Smart Logic Action [38] Set dig. out. A
high is executed. The input will go low whenever the Smart Logic Action [32] Set dig. out. A low is
executed.
SL Controller Action. The input will go high whenever the Smart Logic Action [39] Set dig. out. A
high is executed. The input will go low whenever the Smart Logic Action [33] Set dig. out. A low is
executed.
SL Controller Action. The input will go high whenever the Smart Logic Action [40] Set dig. out. A
high is executed. The input will go low whenever the Smart Logic Action [34] Set dig. out. A low is
executed.
®
MG.33.M8.02 - VLT
is a registered Danfoss trademark
CANopen DSP 402
[7], please refer to the Operating Instructions for
FC 300 Programming Guide