FC 300 Programming Guide
[41]
Below reference, low
[42]
Above ref, high
[43]
Extended PID Limit
[45]
Bus ctrl.
[46]
Bus ctrl, 1 if timeout
[47]
Bus ctrl, 0 if timeout
[51]
MCO controlled
[60]
Comparator 0
[61]
Comparator 1
[62]
Comparator 2
[63]
Comparator 3
[64]
Comparator 4
[65]
Comparator 5
[70]
Logic rule 0
[71]
Logic rule 1
[72]
Logic rule 2
[73]
Logic rule 3
[74]
Logic rule 4
[75]
Logic rule 5
[80]
SL digital output A
[81]
SL digital output B
[82]
SL digital output C
[83]
SL digital output D
[84]
SL digital output E
Active when actual speed is below speed reference setting.
Active when actual speed is above speed reference setting.
Controls digital output/relay via bus. The state of the output is set in par. 5-90 'Digital & Relay Bus
Control'. The output state is retained in the event of bus time-out.
Controls output via bus. The state of the output is set in par. 5-90
the event of bus time-out the output state is set high (On).
Controls output via bus. The state of the output is set in par. 5-90
the event of bus time-out the output state is set low (Off).
Active when a MCO 302 or MCO 305 is connected. The output is controlled from option.
See par. group 13-1* (Smart Logic Control). If Comparator 0 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-1* (Smart Logic Control). If Comparator 1 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-1* (Smart Logic Control). If Comparator 2 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-1* (Smart Logic Control). If Comparator 3 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-1* (Smart Logic Control). If Comparator 4 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-1* (Smart Logic Control). If Comparator 5 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-4*(Smart Logic Control). If Logic Rule 0 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-4*(Smart Logic Control). If Logic Rule 1 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-4*(Smart Logic Control). If Logic Rule 2 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-4*(Smart Logic Control). If Logic Rule 3 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-4*(Smart Logic Control). If Logic Rule 4 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. group 13-4*(Smart Logic Control). If Logic Rule 5 in SLC is TRUE, the output will go high.
Otherwise, it will be low.
See par. 13-52 'Smart Logic Control Action'. Output A is low on Smart Logic Action [32]. Output A
is high on Smart Logic Action [38].
See par. 13-52 'Smart Logic Control Action'. Output B is low on Smart Logic Action [33]. Output B
is high on Smart Logic Action [39].
See par. 13-52 'Smart Logic Control Action'. Output C is low on Smart Logic Action [34]. Output C
is high on Smart Logic Action [40].
See par. 13-52 'Smart Logic Control Action'. Output D is low on Smart Logic Action [35]. Output D
is high on Smart Logic Action [41]
See par. 13-52 'Smart Logic Control Action'. Output E is low on Smart Logic Action [36]. Output E
is high on Smart Logic Action [42].
®
MG.33.M8.02 - VLT
is a registered Danfoss trademark
3 Parameter descriptions