3 Parameter descriptions
3
7-07 Speed PID Feedback Gear Ratio
Range:
1.0000*
[Application dependant]
7-08 Speed PID Feed Forward Factor
Range:
0 %*
[0 - 500 %]
3.9.3 7-1* Torque PI Control
Parameters for configuring the torque PI control in torque open loop (par. 1-00
7-12 Torque PI Proportional Gain
Range:
100 %*
[0 - 500 %]
130
Function:
Function:
The reference signal bypasses the speed controller by the amount specified. This feature increases
the dynamic performance of the speed control loop.
Configuration Mode
Function:
Enter the proportional gain value for the torque controller. Selection of a high value makes the
controller react faster. Too high a setting leads to controller instability.
®
MG.33.M8.02 - VLT
is a registered Danfoss trademark
FC 300 Programming Guide
).