Power Failure Transfer; Table 3-1 Power Failure Transfer Connections - NEC Univerge SV9100 System Hardware Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

2.5
3-4
The system requires a dedicated 100 - 240 VAC 50/60 Hz circuit located within
seven feet of the AC receptacle. Telco should install the RJ21X to the right of the
Controlling Chassis. Extension blocks should be installed to the left of the
Controlling Chassis.
Chassis are shipped fully assembled. The following are included with the chassis:
19" Chassis (CHS2UG)
One black 3-prong power cord (packed outside the chassis)
CHS2UG RACK MOUNT KIT
9.5" Gateway Chassis (CHS2UG GW)
One black 3-prong power cord (packed outside the chassis)
Wall Mount Kit
Stand Mount Kit
9.5" Base and Expansion Chassis (CHS2UG B and CHS2UG E)
One black 3-prong power cord (packed outside the chassis)
Wall Mount Kit
Stand Mount Kit

Power Failure Transfer

The Power Failure Transfer relays are located on the COIU blades (CN3). When
selecting a Single Line Telephone for power failure transfer, make sure it matches
the CO line dialing type (10 pps, 20 pps, or DTMF) where it is connected. Each
COIU blade supports two power failure transfer connections. During a power
failure condition, CO Ports 1 and 2 on the COIU Blade are used for Power Failure
Transfer relays 1 and 2 consecutively.
Connections
is a relay diagram. The relay is shown with the power ON.
Power Failure and FAX Branch Connection do not function
simultaneously on the same port. Use Program 14-02-21 (Fax Branch
NOTE
Connection) to enable this feature per trunk.

Table 3-1 Power Failure Transfer Connections

Pin Number
1
Not in Use
3
Tip for Circuit 2
5
Tip for Circuit 1
7
Not in Use
Table 3-1 Power Failure Transfer
Description
Pin Number
2
4
6
8
Issue 2.0
Description
Not in Use
Ring for Circuit 1
Ring for Circuit 2
Not in Use
Installing the SV9100 Chassis