8 AUXILIARY AND APPLIED FUNCTIONS

8.7.2 Individual start

[Control details]
JOG operation for the specified axes is started.
JOG operation is executed by the following JOG operation commands :
• Forward JOG start command........... M3202+20n
• Reverse JOG start command........... M3203+20n
(1) JOG operation continues at the JOG speed setting register value while the JOG
operation signal turns on, and a deceleration stop is made by the JOG operation
signal OFF.
Control of acceleration/deceleration is based on the data set in the JOG operation
data.
JOG operation command
(M3202+20n/M3203+20n)
JOG operation for axis for which JOG operation command is turning on is
executed.
V
Acceleration based
on JOG operation
data
ON
OFF
8 - 61
JOG operation speed
Deceleration stop based
on JOG operation data
t