Specifications Of Led • Switch - Mitsubishi Electric Q172CPU Programming Manual

Melsecq series motion controller sv43
Hide thumbs Also See for Q172CPU:
Table of Contents

Advertisement

10 ROM OPERATION FUNCTION
10.2 Specifications of LED • Switch
Side face
No.
Name
1) MODE LED (Mode judging)
2) RUN LED
3) ERR. LED
4) M.RUN LED
5) BAT. LED
6) BOOT LED
(1) Name of parts
• Lit(green)
: Normal mode
• Lit(orange)
: Installation mode • mode written in ROM
• Lit
: Motion CPU normal start
• Not lit
: Motion CPU fault
LED turns off when the trouble occurred at Motion CPU start or WDT error
occurred.
• Lit
: LED turns on at following errors occurrence.
• Flickers
: Detection of self diagnostic error which will stop the operation.
• Not lit
: Normal
• Lit
: During motion control
• Flickers
: Latch clear start
• Not lit
: Not during motion control or detection of self diagnostic error which will stop the
operation.
• Lit
: Battery error occurrence (External battery use)
• Lit
: Mode operated by ROM
• Not lit
: Mode operated by RAM/Installation mode • mode written in ROM
Front face
Q17 CPU(N)
MODE
RUN
ERR.
M.RUN
BAT.
BOOT
FRONT
SSCNET
CN2
CN1
PULL
USB
RS-232
Put your finger here to open
the cover.
Application
1) WDT error
2) System setting error
3) Servo error
4) Self diagnostic error which will not stop the operation (except battery error).
5) Operating system software is not installed.
10 - 3
With front cover open
1)
MODE
10)
RUN
2)
ERR.
3)
M.RUN
BAT.
4)
BOOT
5)
ON SW
1
6)
2
3
4
5
STOP
RUN
RESET L CLR
9)
7)
8)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q173cpuQ172cpunQ173cpun

Table of Contents