APPENDICES
No.
Name
M9000 Fuse blown detection
M9005 AC/DC DOWN detection
M9006 Battery low
M9007 Battery low latch
M9008 Self-diagnostic error
M9010 Diagnostic error
M9025 Clock data set request
M9026 Clock data error
M9028 Clock data read request
M9036 Always ON
M9037 Always OFF
M9060 Error reset
M9073 PCPU WDT error flag
PCPU READY complete
M9074
flag
M9075 Test mode ON flag
External forced stop
M9076
input flag
Special relay list
Meaning
OFF : Normal
Turn on when there is one or more output modules control
ON
: Fuse blown module
of self CPU which fuse has been blown.
detected
Remains on if normal status is restored.
• Turn on if a momentary power interruption of less than
OFF : AC/DC DOWN
20ms occurred during use of the AC power supply
not detected
module, and reset by turning power off to on.
ON
: AC/DC DOWN
• Turn on if a momentary power interruption of less than
detected
10ms occurred during use of the DC power supply
module, and reset by turning power off to on.
• Turned on when the voltage of the external battery
reduces to less than specified value. Turn off when the
OFF : Normal
voltage of the external battery becomes normal.
ON
: Battery low
• Synchronizes with "BAT. LED"
• Check the voltage of the external battery, only when it is
set with "external battery use" by system setting.
• Turn on when the voltage of the external battery reduces
to less than specified value. Remains on if normal status is
OFF : Normal
restored.
ON
: Battery low
• Synchronizes with "BAT. LED"
• Check the voltage of the external battery, only when it is
set with "external battery use" by system setting.
OFF : No error
• Turn on when error is found as a result of self-diagnosis.
ON
: Error
Remains on if normal status is restored.
OFF : No error
• Turn on when error is found as a result of diagnosis.
ON
: Error
Remains on if normal status is restored.
OFF : Ignored
• Write clock data stored in D9025 to D9028 to the clock
ON
: Set request present
element when M9025 has changed from off to on.
used
OFF : No error
• Turn on by clock data (D9025 to D9028) error.
ON
: Error
OFF : Ignored
• Read clock data from D9025 to D9028 in BCD when
ON
: Read request
M9028 is on.
ON
• Turn on without regard to position of RUN/STOP switch
OFF
on.
ON
• Turn off without regard to position of RUN/STOP switch
OFF
on.
OFF
ON : Error reset
• A release of the error is executed.
• Turn on when a "watchdog timer error" is detected by the
Motion CPU self-diagnosis function.
When the Motion CPU detects a WDT error, it executes
ON
: Abnormal
an immediate stop without deceleration of the operating
OFF : Normal
axes.
• The error cause is stored in the "Motion CPU WDT error
cause (D9184)".
• When the PLC ready flag (M2000) turn off to on, the
ON
: PCPU READY
fixed parameters, servo parameters and limit switch
completion
output data, etc., are checked, and if no error is detected
OFF : PCPU READY
this flag turns on.
uncompletion
• Turn off when the PLC ready flag (M2000) turns off.
• This flag status indicates whether a TEST mode
ON
: TEST mode is in
established from a peripheral device is currently in
effect.
effect.
OFF : TEST mode is not in
• If the TEST mode is not established in response to a
effect.
TEST mode request from a peripheral device, the
"TEST mode request error flag (M9078)" will turn on.
ON
: Forced stop OFF
• This flag status indicate whether the forced stop.
OFF : Forced stop ON
Details
(Note-1) : It adds newly at the Motion controller Q series.
APP - 65
Set by
Remark
(When set)
S (Occur an error)
New
(Note-1)
U
S (Request)
U
S (Main processing)
New
U
(Note-1)
S (Occur an error)
S (Request)
S (Request)
S (Operation cycle)