G23 Cancel, Cancel Start Invalid - Mitsubishi Electric Q172CPU Programming Manual

Melsecq series motion controller sv43
Hide thumbs Also See for Q172CPU:
Table of Contents

Advertisement

7 MOTION PROGRAMS FOR POSITIONING CONTROL

7.13.13 G23 Cancel, cancel start invalid

Code
Function
Cancel, cancel start invalid
G
23
Format
[Explanation]
[Program Example]
G23
;
(1) This command makes invalid the cancel or cancel start function which has already
been made valid.
(2) This function is also made valid for the high-speed oscillation axis.
N1 G24 CAN #X100 ;
N2 G01 X200. F200. ;
N3 G25 Y START90. STRK1. F10 ;
N4 G23 ;
The program which makes the cancel start function valid/invalid during execution of
"O0010" program.
O0010
G24 CAN #X100 P100 PB1 ;
G90 G01 X200. F1000. ;
G23 ;
G24 (cancel function, cancel start function) which has already been
made valid is invalidated.
Valid until G24 (cancel function, cancel start function) is executed.
Execution of cancel start function
Cancel start function invalid
7 - 79
Cancel function is valid for N2 and N3.
Cancel function is invalid
(Cancel function is invalid for the high-
speed oscillation axis.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q173cpuQ172cpunQ173cpun

Table of Contents