Positioning Control Unit For 1 Axis - Mitsubishi Electric Q172CPU Programming Manual

Melsecq series motion controller sv43
Hide thumbs Also See for Q172CPU:
Table of Contents

Advertisement

7 MOTION PROGRAMS FOR POSITIONING CONTROL

7.11.5 Positioning control unit for 1 axis

REMARK
(1) Command unit
A decimal point can be entered in the Motion program input information which
defines the command address or speed, etc.
[Example] 123456.7890
A decimal point may also be omitted.
When a decimal point is omitted, a command address is represented in
0.0001[mm], 0.00001[inch] or 0.00001[degree] increments, for example.
<For command address>
[Example] 10. ······ 10mm
10 ······· 0.001mm (unit: mm)
Any value may be specified up to 10 digits. (Decimal point not included) Specifying
more than 10 digits will result in an error.
The numbers of significant decimal places are listed below. Digits after the
significant decimal places are ignored. Note that specifying 10 or more digits will
result in an error.
Command
Command address
Command speed
For one axis, positioning control is executed in the control unit specified in the fixed
parameter.
(The control unit specified in the parameter block is ignored.)
<For feed speed (F)>
.
[Example] 10. ······ 10mm/min
Unit
mm
4
2
7 - 43
.
10 ······· 0.1mm/min (unit: mm)
inch
degree
5
5
3
3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q173cpuQ172cpunQ173cpun

Table of Contents