Chapter 33 switch Commands
This command sets a list of maintenance association end points. The following example sets the
end point identifier "2" in the list of end point identifiers for the maintenance association "ma1" in
the maintenance domain "md1".
ras> switch cfm ma meplist set md1 ma1 2
33.5.3.9 switch cfm ma set
Syntax:
switch cfm ma set <md-name> <ma-name> <primary-vlan> [<cci-interval>]
where
<primary-vlan> =
<cci-interval> =
This command sets a maintenance association. The following sets up the maintenance association
"ma1" with the primary VLAN identified by 2 and a CCI interval of 7 (10 minutes).
ras> switch cfm ma set md1 ma2 2 7
33.5.3.10 switch cfm ma vlan delete
Syntax:
switch cfm ma vlan delete <md-name> <ma-name> <vlan-id>
This command deletes a VLAN from a maintenance association. The following example deletes the
VLAN identified by 3 from the maintenance association "ma1".
ras> switch cfm ma vlan delete md1 ma1 3
33.5.3.11 switch cfm ma vlan set
Syntax:
switch cfm ma vlan set <md-name> <ma-name> <vlan-id>
This command adds a VLAN into a maintenance association. The following example sets the VLAN
identified by 3 in the maintenance association "ma1".
ras> switch cfm ma vlan set md1 ma1 3
996
The primary served VLAN of this association.
The continuity check message initiation interval. The range is 4~7 where:
4: 1 s
5: 10 s
6: 1 min
7: 10 min