Appendix 5 Improvement Of Web Server Module Functions; Appendix 5.1 Functions Added To/Changed From Old Version - Mitsubishi Electric MELSEC Q Series User Manual

Programmabale web server module
Hide thumbs Also See for MELSEC Q Series:
Table of Contents

Advertisement

APPENDICES

Appendix 5 Improvement of Web Server Module Functions

Appendix 5.1 Functions added to/changed from old version

Added/Changed Function
Network connection form
Connection component
E-mail setting
I/O signal details
Buffer memory list
System setting
Account setting
IP filter setting
Access target CPU setting
Intelligent function module
switch setting
App - 15
This section explains the functions added to/changed from the old version by the
improvement of the Web server module functions, and provides the precautions for
replacing the old version with the new version.
This section explains the functions added to/changed from the old version.
(1) Module with first 5 digits of serial No. 05112 or later
 The following network connection forms are available.
1) Connection via a router type ADSL modem
2) Connection via a bridge type ADSL modem + broadband router
 The following connection components are available.
1) ADSL modem in which the protocol is "PPPoE" or "PPPoA"
2) Broadband router
3) UPnP compatible
 POP before SMTP are available.
 A change was made to clear the current error area (address: 140 to
145) of the buffer memory by turning on Error clear request (Y10).
 The areas indicated in Section 3.7 ( 1) were added.
 The following setting items were added.
1) The "Register the above port No. to the router's NAT" check box
was added to the Web server setting.
2) "FTP server setting"
3) "System name setting"
4) "Network diagnosis setting"
 The following setting items were changed.
1) The "Network type setting" setting field was moved to the top.
2) "Connecting through LAN." was changed to "Connecting through
LAN or the router".
 "Initial screen" was added to the setting item.
 "Access authority: Write" was divided into "Device write" and "Tag
component write".
 This setting screen was added.
 "Different network communication route" was added as a setting
item.
 A change was made to make the default operation setting (Bit 1 of
Switch 2) valid for "IP filter setting".
 The logging monitor setting (Bit 4 of Switch 2) was added.
Description
MELSEC-Q
Reference
Section
Section 2.2
Section 2.4
Section 3.6.2
Section 3.7,
Section 3.8
Section 4.6.3
Section 4.6.5
Section 4.6.6
Section 4.6.7
Section 4.7
(Continued on the next page)
App - 15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec qj71ws96

Table of Contents