4.
To locate the failed DIMM, press and hold the Fault Remind button [1].
Call Out
1
2
3
5.
Verify that the green Fault Remind Power indicator [2] is lit.
The Charge Status indicator [2] lights if the Fault Remind circuit is operational.
The Fault Remind circuit remains charged for about 10 minutes after power is removed from
the CMOD, either by disconnecting power from the server, or by removing the CMOD from the
chassis. When you press the Fault Remind button, the Charge Status indicator lights if there is
enough power to use the fault remind circuit. Otherwise it remains dark.
6.
With the Fault Remind button pressed, look for a lit DIMM fault indicator [3].
The indicators are located next to the DIMM slots.
Description
Fault Remind button
Fault Remind Power indicator
DIMM slot fault indicator (one for each slot)
Replace a Failed DIMM
Servicing Components
149