Power Off, Immediate (Power Button)
Caution -
five seconds. Doing so initiates an immediate server shutdown. Press and release the button
immediately.
2.
Verify that the server is in standby power mode.
When the server is in standby power mode, the SP indicator is on steady, and the Power OK
indicator blinks at the single blink rate (a quick flash every three seconds).
"Performing Electrostatic Discharge and Static Prevention Measures" on page 90
Next Steps
■
Power Off, Immediate (Power Button)
Note -
panel.
An immediate shutdown should be used in situations when you know that the loss of data
is nonexistent or acceptable (for more information, see
Resets" on page
Caution -
close all applications before powering off.
102
Oracle Server X5-8 Service Manual • December 2015
Potential for loss of data. Do not press in and hold the power button for longer than
This procedure is performed locally and requires physical access to the server front
107).
Data loss. All applications and files close abruptly without saving. Warn users and
"Power Modes, Shutdowns, and