PSU Failure
For a server with a PSU in a failed state, the server amber Service Action Required indicators
(front and back) and the amber Servic Action Required indicator on the PSU are on steady. The
front and back green Power OK indicator and the green SP indicator are on steady.
For indicator blink rate information, see
Memory Failure
For a server with a failure in the memory subsystem, the server amber Service Action Required
indicators (front and back) and an amber CMOD Service Action Required indicator are on
steady. The front and back green Power OK indicator and the green SP indicator are on steady.
For indicator blink rate information, see
CPU Failure
For a server with a fault in the processor subsystem, the server amber Service Action Required
indicators (front and back) and an amber CMOD Service Action Required indicator are on
steady. The activity of front and back green Power OK indicator and the green SP indicator vary
depending on whether the server can boot successfully. The server might not be able to boot out
of standby power mode.
For indicator blink rate information, see
Fan Module Failure
For a server with a fan module fault, the server amber Service Action Required indicators (front
and back) and an amber Service Action Required indicator on a fan module are on steady. The
front and back green server OK indicator and the green SP indicator are on steady.
For indicator blink rate information, see
SP Failure
For a server with an SP fault, the server amber Service Action Required indicators (front and
back) are on steady. The front and back System OK indicators and the SP OK indicator are off.
"Indicator Blink Rates" on page
"Indicator Blink Rates" on page
"Indicator Blink Rates" on page
"Indicator Blink Rates" on page
"Indicator Blink Rates" on page
Troubleshooting and Diagnostics
Troubleshoot Hardware Faults