Sony MVS-8000X User Manual page 794

Multi-format production switcher processor with ccp-8000 series center control panel volume 1
Hide thumbs Also See for MVS-8000X:
Table of Contents

Advertisement

3
4
794
Recalling a Register
[MCRO]: This selects Macro.
[DEV 1] to [DEV 12]: This selects device.
[ALL]: This selects all valid regions.
[MSTR]: This selects the master timeline (see "Creating and Saving a
Master Timeline Using the Buttons in the Multifunction Flexi Pad
Control Block" (page 832)).
Notes
The regions that can be selected simultaneously are those assigned to the
region selection buttons in the Multifunction Flexi Pad control block, and
those displayed on the memory recall section buttons when the [MORE]
button is pressed. (See "Assigning a Region to a Region Selection Button
in the Numeric Keypad Control Block or Multifunction Flexi Pad Control
Block" in Chapter 19 (Volume 3).)
When [MSTR] and other regions are selected simultaneously, the master
timeline takes precedence.
The first button pressed lights green as the reference region, and any
subsequently pressed buttons light amber.
Pressing one of the amber-lit buttons, while holding down [EFF], turns the
button green to indicate its corresponding region as the new reference
region.
For details of the precedence order for becoming the reference region, see
"Reference region" (page 767).
The display shows the name of the reference region, and the number of the
last register recalled for this region.
Enter the number of the register you want to recall, using the numeric
keypad.
To find an empty register, instead of entering a number, press the [.]
(period) button. To search for an empty register common to all currently
selectable regions, press the [.] button again.
To search for an empty register in the 100 range, press [1], [0], [0], [.]
(period) in this order. Similarly, to search for an empty register in the 200
range, press [2], [0], [0], [.] (period), and to search for an empty register in
the 300 range, press [3], [0], [0], [.] (period).
The register number appears in the display. If the number is followed by a
letter 'e' or 'E,' this indicates the following.
e: The selected register is empty for the regions selected in step 2.
E: The selected register is empty for all currently selectable regions.
Press the [ENTR] button.
This recalls the specified register.

Advertisement