6
Selectable actions for various trigger types
• When the trigger type is other than "Level"
• When the trigger type is only "Rising Edge" or "Falling Edge"
• When the trigger type is "Level"
Notes
• "Level Enable" is a function that determines whether GPI inputs are enabled
• As for "Aux ? O'ride Src ??," when "Rising Edge" is selected, on a rising
1144
Interfacing With External Devices (Device Interface Menu)
For format converter dedicated inputs: 165 to 180 ((FC1) to (FC16) indicated after the
number)
Press [Action Set] to confirm the action selection.
The selected setting appears in the status area.
(In M/E-x, the x is the M/E bank number (1 to 4); in DSKx the x is the DSK
number (1 to 8); in Keyx the x is the key number (1 to 8)).
When Target is M/E-x: Cut, Auto Trans, Keyx Cut, Keyx Auto Trans,
Keyx SS ? Recall
When Target is P/P: Cut, Auto Trans, DSKx Cut, DSKx Auto Trans,
DSKx SS ? Recall, FTB Auto Trans, FTB Cut
When Target is Common/Setup:
Master SS ? Recall, Master Effect ? Recall, SS ? Recall, Effect ?
Recall, Effect ? Recall & Run, KF Run, KF Stop, KF Rewind, FM
Src1 Frame Freeze, FM Src1 Field Freeze, FM Src1 Freeze Off, FM
Src2 Frame Freeze, FM Src2 Field Freeze, FM Src2 Freeze Off, FM
Src1 Clip Record, FM Src1 Clip Stop, FM Src2 Clip Record, FM Src2
Clip Stop, FM1 to FM8 Clip Cueup, FM1 to FM8 Clip Play, FM1 to
FM8 Clip Stop, Shotbox ? Recall, Macro Take, Prefs Button?, Macro
? Recall, No Action
Aux? O'ride Src??
When Target is M/E-1, M/E-2, M/E-3, M/E-4 or P/P: No Action
When Target is Common/Setup: System Format
Aspect (overall system settings), Level Enable, No Action
("Enable") or disabled ("Disable") for the "Aspect" and "Format" actions
that can be used when the trigger type is Level. When Level Enable is used,
if the input is "Disable" then it is not possible to switch "Aspect" or "Format"
by GPI input.
If a GPI to switch "Aspect" or "Format" occurs when powering the system
off, the action triggered by the GPI may start immediately before the power
goes off and the power may go off before the action is completed. This may
corrupt the setup settings. It is therefore recommended to use Level Enable
to avoid such a situation.
edge the set AUX bus input is used. On a falling edge, the original state of
the cross-point is restored. If the GPI trigger is applied repeatedly at short
intervals (0.5 second or less), the cross-point switching may not be carried
out correctly. In this case, apply the GPI trigger again.