Assigning a Cross-Point Button to Enable/Disable Side
Flags
By assigning the side flag function to the rightmost button in a cross-point
button row, you can use this button to enable/disable side flags for each of the
M/E and PGM/PST banks.
This setting applies to all of the M/E and PGM/PST banks.
When you make this assignment, the SHIFT button (the button assigned to the
shift function) is moved one to the left.
Notes
If a macro attachment is set, when you assign the button to the side flag
function, the button numbers are offset, and therefore when you press the
button this does not execute the macro. The settings, however, are maintained,
so that when you cancel the side flag assignment, the macro can be accessed
once more.
SHIFT button moves
one to the left
For details of side flag operations, see "Side Flag Settings" in Chapter 10
(Volume 1).
1
In the Panel >XPT Assign menu, press [Side Flags Button Assign].
The Side Flags Button Assign menu appears.
2
Press [Side Flags Btn Assign], turning it on.
This assigns the rightmost cross-point button to enabling/disabling the side
flag function.
Button for side flags
enable/disable