Procedure for Simple Connection

To connect the MKS-8080/8082 AUX Bus Remote Panel to the center control
panel using an S-Bus data link requires a BKPF-R70A Routing Switcher
Controller Board or similar primary station and various settings for connection.
However, using a simple connection, the need for an S-Bus data link primary
station is avoided, and direct connection to the MKS-8080/8082 is possible.
A simple connection is possible if the following conditions are met:
• There are no devices other than the center control panel and MKS-8080/8082
• There are no more than 16 MKS-8080/8082 units connected on the S-Bus
To carry out simple connection of the MKS-8080/8082 AUX Bus Remote
Panel, use the following procedure.
For settings on the MKS-8080/8082, see the section "Making the Setting With
Buttons (Setup Function)" in the Operation Manual for the MKS-8080/8082.
1
2
3
4
5
1264
Procedure for Simple Connection
connected on the S-Bus data link.
data link.
Carry out initialization of the MKS-8080/8082 settings.
This can be done on the MKS-8080/8082 separately.
Set the MKS-8080/8082 station number in the range 2 to 17.
This can be done on the MKS-8080/8082 separately.
Set the S-Bus data link primary station to the center control panel by
setting the STATION ID switches on the front of the board in the SCU
SLOT 1 to 001 (switch 1 only to the OPEN position).
System control unit
MKS-8010A
MKS-8010B
In the Engineering Setup >System >Initialize menu, select PNL, and carry
out a reset.
This carries out a restart, and when the restart is completed connection to
the MKS-8080/8082 is possible.
In the Engineering Setup >Router/Tally >Router menu, set the position of
the MVS-8000X system in S-Bus space.
Select the setting from SWR1 and SWR2, and set each of Source,
Destination, and Level to 1.
Board
FP-141
CA-76
STATION ID switches
S108
S9108