• Press directly on the list in the status area.
• Press the arrow keys to scroll the reverse video cursor.
• Turn the knob.
Knob
1
The selected output signal appears in reverse video.
Adjusting the video clip
To adjust the clip value for each of the output signals from the Output 1 to 48
ports, use the following procedure.
1
In the Switcher >Output menu, press [Video Clip].
The Video Clip menu appears.
The status area shows the output ports and assigned signals, and the white
clip, dark clip, and chrominance clip values.
2
Adjust the following parameters.
Knob
2
3
4
To set the values to the default values, press [Default].
Making vertical blanking interval adjustment and through mode
settings
1
In the Switcher >Output menu, press [V Blank/Through].
The V Blank/Through menu appears.
The status area shows the output ports and the assigned signals, the vertical
blanking interval, and the through mode Enable/Disable status.
2
Press [V Blank Mask].
3
Adjust the parameter.
Knob
2
a) Depending on the signal format, the adjustment range varies as follows.
Parameter
Adjustment
Output No
Output port number selection
Parameter
Adjustment
White Clip
Luminance signal white clip value
Dark Clip
Luminance signal dark clip value
Chroma Clip Chrominance signal clip value
Parameter
Adjustment
Mask End
Final value for vertical blanking
interval
Setting values
1 to 48
Setting values
90.00 to 109.02
–6.85 to +10.00
90.00 to 113.17
Setting values
See note a) below