Notes
It is not possible to assign the combinations of Main with Main&Sub, or Sub
with Main&Sub.
Assigning the [MAIN] and [SUB] delegation buttons to buttons
on the control panel
To assign the Main/Sub switching function to buttons in the
transition control block
This applies to the standard type and compact type transition control block, and
the CCP-6224/6324 control panel.
For details of the transition control block, see page 59 (for the standard type)
or page 104 (for the compact type).
For details of the CCP-6224 2M/E control panel, see page 107, and for the
details of the CCP-6324 3M/E control panel, see page 107.
1
2
3
4
484
Multi Program 2
In the status area of the Engineering Setup >Panel >Config >MP2 Main/
Sub Assign menu, select 1st Row (M/E-1), then press [Main] in the <Main/
Sub Assign> group.
Press [Dual M/E Assign] to assign M/E to two banks.
In this state, both 1st Row and 2nd Row are set to main.
Set 2nd Row to [Sub].
This cancels the shift/non-shift assignment for dual M/E in standard mode.
In the Engineering Setup >Panel >Config menu, press [Program Button].
The Program Button menu appears.
Press [Transition Module 1].
The Transition Module 1 menu appears.
Select the switcher bank in the <Bank Select> group.
The buttons in the transition control block on the left appear in the
currently assigned state.
Press the button whose assignment you wish to change.
The button you press appears in reverse video.