34
en | Settings
6

Settings

This chapter describes the settings of the AMAX panel in the same order as they appear in the
menu structure of the text keypad. For an overview of the menu structure, refer to Text Keypad
Programming, page 86.
The settings can be configured either via a text keypad or via the PC software A-Link Plus.
For information on how to configure the settings via a text keypad and how to navigate a text
keypad, refer to Text Keypad Programming, page 86.
For information on how to connect the AMAX panel to a PC, refer to PC Programming, page
98.
6.1

Communication and Reporting

This section outlines the programming information required for the AMAX panel when
communicating with a base station receiver. These parameters specify the telephone
numbers/IP address to be called, transmission formats, and internet communication options.
6.1.1

Receivers

Receiver Telephone number / IP Address and Port
The AMAX panel can report event information from an on-board dialer, which can call four
different receivers and four different telephone numbers. The dialer reports to receiver 1 to 4
by programming. You can program the dialer with 4 separate telephone numbers/IP addresses
and ports, reporting format type and subscriber ID number, and internet communication
options if necessary.
Example
You can set up dialer 1 to report to receiver 1 in Bosch Network (Conettix) format and set up
dialer 2, dialer 3, and dialer 4 to report to a receiver of a central monitoring station in Contact
ID format only, if dialer 1 is unsuccessful.
How to program a telephone number via a text keypad:
1.
2.
How to program a telephone number via address programming:
1.
2.
3.
Example for address programming
The following table shows how to program the numbers, keys, and functions for a telephone
number via address programming or via installer menu programming.
2015.05 | 06 | F.01U.309.277
All manuals and user guides at all-guides.com
Enter the digits of a telephone number in the text keypad.
To enter a 4-sec pause in the dialing sequence, enter [*] [3].
A pause might be necessary when the dialer communicates through an old (slower)
telephone exchange or when a PABX system is in place.
Enter one digit of a telephone number in each address for the telephone numbers.
To enter a 4-sec pause in the dialing sequence, insert "13".
A pause might be necessary when the dialer communicates through an old (slower)
telephone exchange or when a PABX system is in place.
To terminate the input, insert "15".
To program the telephone number "9672 1055" as the telephone number for receiver 1,
program the following sequence into address 000 - 016:
[9 6 7 2 1 0 5 5 15 x x x x x x x x] (x stands for any digit)
To program the number "02 pause 9672 1055", program the following sequence into
address 000 - 016:
[0 2 13 9 6 7 2 1 0 5 5 15 x x x x x]