2.11.5 Access Control Levels; L## Perimeter O/C; L## Send Duress; L## Passcode Arm - Bosch D9412GV2 Program Entry Manual

Table of Contents

Advertisement

D9412GV2/D7412GV2 | Program Entry Guide | 2.0

L## Perimeter O/C

Default:
Refer to the program record sheet
Selection:
Blank or E
Generates Perimeter Opening and Closing Reports if
the area where this authority level is assigned sends
Perimeter Opening and Closing Reports.

L## Send Duress

Default:
Refer to the program record sheet
Selection:
Blank or E
Generates a Duress Report if the area where this
authority level is assigned sends duress. (Refer to the
A# Duress Enable
prompt in Section 2.9.5 Open/Close
Options on page 39.)

L## Passcode Arm

Default:
Refer to the program record sheet
Selection:
Blank or E
Arm an area by entering a pass code and pressing
[ENTER].

L## Passcode Disarm

Default:
Refer to the program record sheet
Selection:
Blank or E
Disarm an area by entering a pass code and pressing
[ENTER].

2.11.5 Access Control Levels

L## Security Level

Default:
Refer to the program record sheet
Selection:
M, P, D, or Blank
M
Users have access rights for this area
when the area is in any armed state.
P
Users have access rights for this area
when the area is Perimeter Armed or
Disarmed but not while the area is
Master Armed.
D
Users have access rights for this area
only while it is disarmed.
Blank
Users do not have access rights to this
area.
Security Level [TOKEN FUNCTION]
When the user presents a token or card at the reader,
access is granted only when the user has the authority
to enter the area under certain armed conditions.
Bosch Security Systems | 5/05 | F001U003636B
GV2MAIN

L## Disarm Level

Default:
Refer to the program record sheet
Selection:
I, D, or Blank
I
Users change the Master Armed state
and Perimeter Armed state to
Perimeter Instant. The armed state
does not change in other areas, and
the armed state does not change if the
area is already in the perimeter
instant or disarmed state. User needs
access level for Master Armed (M)
state.
D
Users change the local area's Master
Armed state and Perimeter Armed
state to the Disarm state. User needs
access level for Master Armed (M) or
Perimeter Armed (P) state. All areas
within the scope of the keypad
assigned to the
the access handler, and areas to
which the user has disarm rights,
disarm as programmed.
Blank
Users do not have disarm rights in
this area.
Burglar bells are silenced in the local area
when a user disarms with a token or card or
presents the token or card during an alarm.
The user must use a pass code to silence a
Fire Bell. Cancel Reports are sent after a
valid pass code or token or card silences
the bell.
Opening and Closing Reports are sent to
the central station receiver if programmed.
For more information on programming this
prompt for a shared area, refer to Access
Control Readers Assigned to the Shared
Area in Section 2.9.3 Shared-Area
Characteristics on page 37.
EN | 69
D# CC# Scope
in

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D7412gv2

Table of Contents