82-12: Opx Initial Data Setup (Au) - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Program 82 : Basic Hardware Setup for Extension
Level:
IN
Description
Use Program 82-12: OPX Initial Data Setup to define the various initial data for OPX
packages.
Input Data
Ite
m
No.
01
02
03
Feature Cross Reference
None
Programming Manual
Item
Specify a time for detection of
Bounce Protect
Time
a valid off-Hook indication that
is long enough to prevent an
unintentional bounce of the
receiver from being detected
as a new Off-Hook indication
from a single line telephone.
Specify the minimum
HookFlash Start
Time
hookflash time from a single
line telephone or analog
Voice Mail system before it is
detected as the beginning of a
valid hookflash.
Specify the maximum
HookFlash End
Time
hookflash duration from a
single line telephone to
receive a second dial tone.
Conditions
None

82-12: OPX Initial Data Setup (AU)

Description
0 = No Setting
1~15 = 100ms~1.5sec
0 = 40ms
1~15 = 90ms~790ms
0 = HST+0ms
1~15=HST+100ms~HST+
1500ms (HST=Hookflash
Start Time)
Issue 10.1
Input
Default
3
(300ms)
0 (40ms)
1
(1600ms)
2 - 753