Field
Level
Info
# (Distributed devices in IRF mode.) Display alarm information.
<Sysname> display alarm
Chassis
Slot
1
6
1
6
1
6
2
3
Table 39 Command output
Field
Chassis
Slot
Level
Info

display clock

Use display clock to display the system time, date, local time zone, and daylight saving time.
Syntax
display clock
Views
Any view
Predefined user roles
network-admin
Description
generated by the chassis. (Centralized devices in IRF mode.)
Alarm severity. Possible values include ERROR, WARNING, NOTICE, and INFO, in
descending order.
Detailed alarm information:
faulty—The card is starting up or faulty.
Fan n is absent—The specified fan is absent.
Power n is absent—The specified power supply is absent.
The temperature of sensor n exceeds the lower limit—The temperature of
the specified sensor is lower than the low-temperature threshold.
The temperature of sensor n exceeds the upper limit—The temperature of
the specified sensor is higher than the high-temperature warning threshold.
CPU
Level
Info
0
ERROR
Fan 2 is absent.
0
ERROR
Power 2 is absent.
1
ERROR
The board in slot 10 is faulty.
1
WARNING
The temperature of sensor 3 exceeds the lower limit.
Description
Member ID of the IRF member device with an alarm.
Slot number of the card.
Alarm severity. Possible values include ERROR, WARNING, NOTICE, and
INFO, in descending order.
Detailed alarm information:
faulty—The card is starting up or faulty.
Fan n is absent—The specified fan is absent.
Power n is absent—The specified power supply is absent.
The temperature of sensor n exceeds the lower limit—The
temperature of the specified sensor is lower than the low-temperature
threshold.
The temperature of sensor n exceeds the upper limit—The
temperature of the specified sensor is higher than the high-temperature
warning threshold.