Examples
# (Distributed devices in standalone mode.) Power off the card in slot 9.
<Sysname> power-supply off slot 9
# (Distributed devices in IRF mode.) Power off the card in slot 3 on member device 1.
<Sysname> power-supply off chassis 1 slot 3

power-supply on

Use power-supply on to power on a card or subcard.
Syntax
Distributed devices in standalone mode:
power-supply on slot slot-number [ subslot subslot-number ]
Distributed devices in IRF mode:
power-supply on chassis chassis-number slot slot-number [ subslot subslot-number ]
Views
User view
Predefined user roles
network-admin
Parameters
slot slot-number: Specifies a card by its slot number. (Distributed devices in standalone mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The
chassis-number argument represents the member ID of the IRF member device. The slot-number
argument represents the slot number of the card. (Distributed devices in IRF mode.)
subslot subslot-number: Specifies a subcard by its subslot number. If you do not specify a subcard,
this command starts power supply to all subcards on the card.
Usage guidelines
The following matrix shows the command and hardware compatibility:
Hardware
MSR954 (JH296A/JH297A/JH298A/JH299A/JH373A)
MSR958 (JH300A/JH301A)
MSR1002-4/1003-8S
MSR2003
MSR2004-24/2004-48
MSR3012/3024/3044/3064
MSR4060/4080
Examples
# (Distributed devices in standalone mode.) Power on the card in slot 9.
<Sysname> power-supply on slot 9
# (Distributed devices in IRF mode.) Power on the card in slot 3 on IRF member device 1.
<Sysname> power-supply on chassis 1 slot 3
Command compatibility
No