all: Specifies all member devices. (Centralized devices in IRF mode.)
all: Specifies all cards. (Distributed devices in IRF mode.)
slot slot-number: Specifies a card by its slot number. (Distributed devices in standalone mode.)
slot slot-number: Specifies an IRF member device by its member ID. (Centralized devices in IRF
mode.)
chassis chassis-number slot slot-number: Specifies a card on an IRF member device. The
chassis-number argument represents the member ID of the IRF member device. The slot-number
argument represents the slot number of the card. (Distributed devices in IRF mode.)
test: Only identifies the ISSU method to be used for the upgrade. If you do not specify this keyword,
the command activates the specified software images.
Usage guidelines
Before you use this command to activate a software image, read the release notes to identify the
licensing requirements for the image. If the image requires a license, make sure the device has a
valid license installed for the image.
An image runs in memory immediately after it is activated. For an activated image to run after a
reboot, you must commit the software change by using the install commit command.
On a distributed device in standalone mode, follow these guidelines:
If you specify the active MPU, the command takes effect on the active MPU and all LPUs.
If you specify the standby MPU, the command takes effect only on the standby MPU.
If the specified files are not saved on the MPU to be upgraded, the command copies the images
to the MPU automatically.
On an IRF fabric of distributed devices, follow these guidelines:
If you specify the global active MPU, the command takes effect on the global active MPU and all
LPUs.
If you specify a standby MPU, the command takes effect on the standby MPU.
If the specified files are not saved on the MPU to be upgraded, the command copies the images
to the MPU automatically.
On an IRF fabric of centralized devices:
If you specify a subordinate member for the command, the command copies the images to the
subordinate member automatically.
On a multichassis IRF fabric:
At reboot, a subordinate device automatically synchronizes the master device's configuration and
status data. You must wait for the synchronization to complete before using the install activate
command on the subordinate device. To identify whether the synchronization is complete, use the
display system stable state command. The synchronization is complete if the System State field
displays Stable.
Examples
# (Centralized devices in standalone mode.) Identify the ISSU method for feature upgrade with
ssh2.bin and the upgrade impact on the device.
<Sysname> install activate feature flash:/ssh2.bin test
Verifying the file flash:/ssh2.bin on the device.....Done.
Upgrade summary according to following table:
flash:/ssh2.bin
Running Version
Beta 1330
New Version
Beta 1331
240