8 Perform service routines via the control panel
8.1 Overview of service routines
Service routine
S001
S002
S002.1
S002.3
S002.4
S002.5
S005
S005.1
S005.2
S0005.3
S005.4
S005.5
S005.6
S005.7
S007
S007.1
S007.2
S007.5
S008
S008.2
S008.3
S008.4
S009
S009.4
S009.5
S009.8
248
8
Perform service routines via the control
panel
8.1

Overview of service routines

8.1.1

List of all service routines available for selection

Function
Radiation without rotary movement, fixed maximum radiation time S. [ → 263]
Radiation without rotary movement, selectable kV/mA level and
maximum radiation time
Radiation without rotary movement; selectable kV/mA level and
maximum radiation time; primary diaphragm in last position
selected
Radiation without rotary movement; selectable kV/mA level and
maximum radiation time; primary diaphragm fully opened with
respect to PAN position.
Radiation without rotary movement; selectable kV/mA level and
maximum radiation time; the primary diaphragm is set to a widened
opening symmetrical to the PAN setting so that the step filter still
remains covered.
Radiation without rotary movement; selectable kV/mA level and
maximum radiation time; primary diaphragm and rotation unit are
in 3D position.
General X-ray tube assembly service
Read/select tube type
Automatic adjustment of preheating
(for internal Sirona purposes only)
Fan test
Temperature sensor test, single tank
Switch off cool-down interval of the single tank
Setting continuous operation of the tube assembly fan
Error logging memory
Display error logging memory
Clearing error logging memory
Enable the CAN bus logging in the Miniweb
Update service
Overview of the module software versions
Input/confirmation of unit serial number
Not required in the current unit version.
Flash file system
Formatting flash file system
Test flash file system
Save/restore DX88 data
Sirona Dental Systems GmbH
Service Manual ORTHOPHOS XG 3D / Ceph
63 03 510 D3352
D3352.076.03.11.02 09.2016
see
S. [ → 265]
S. [ → 265]
S. [ → 267]
S. [ → 269]
S. [ → 271]
S. [ → 272]
S. [ → 272]
S. [ → 272]
S. [ → 275]
S. [ → 276]
S. [ → 276]
S. [ → 278]
S. [ → 280]
S. [ → 280]
S. [ → 282]
S. [ → 283]
S. [ → 286]
S. [ → 286]
S. [ → 287]
S. [ → 288]
S. [ → 288]
S. [ → 289]
S. [ → 290]

Hide quick links: