4 Operation and Configuration
GAP Slice Level
Printing > Advanced > Calibrate > GAP Slice Level
Set the Gap sensor slice level.
The setting procedure is as follows:
1. Use the following formula to calculate the slice level.
[(High level - Low level) x 0.3 + Low level = slice level]
2. Select the GAP Slice Level in the Calibrate menu and press the
button.
/
3. Press the
Slice level to the level calculated in step 1.
4. Press the right soft button to confirm the value.
Note
If you set the Slice level to 0.0 (V), the printer sets the slice level
automatically.
96
CL4NX/CL6NX Operator Manual
buttons to change the Slice level value. Set the