SATO CL4NX Operator's Manual page 156

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

4 Operation and Configuration
RS-232C
Interface > RS-232C
Set the RS-232C connection.
Shows only if the combo interface board is installed.
The setting items are as follows:
1
Interface
2
Baudrate
3
Parameters
4
Flow Control
5
BCC
Note
When Interface is set to RS-232C Reader, you cannot change Baudrate,
Parameters, Flow Control or BCC.
Interface
Interface > RS-232C > Interface
Set the RS-232C interface usage.
The options are as follows:
• RS-232C: Use the RS-232C interface for communicating with computers.
• RS-232C Reader: Select this when you connect the barcode checker
to the RS-232C connector of the printer for the barcode check function.
Note
The message prompting to restart the printer will appear on the online/
offline screen if you have made any changes. In such a case, reboot the
printer to make the setting effective.
Baudrate
Interface > RS-232C > Baudrate
Set the baud rate (bps).
Available to change only if you have selected RS-232C in the Interface menu.
The options are as follows:
• 2400
• 4800
• 9600
• 19200
• 38400
• 57600
• 115200
154
CL4NX/CL6NX Operator Manual
Set the RS-232C interface usage.
Set the communication speed.
Set the data parameters.
Set the communication protocol.
Set the BCC check function.
*Shows only if you have selected STATUS5 in
the Flow Control menu.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cl6nx

Table of Contents