Message
CHIP MAKER ERR.
MCS NOT SUPPORT
READ ONLY ERROR
DIFFER TAG KIND
LOST HANDLE ERR
328
CL4NX/CL6NX Operator Manual
Cause and Countermeasure
• Only for UHF
Cause:
Incorrect tag chip maker is specified when specifying the
MCS setting and encoding the SGTIN96.
Countermeasure:
Check the media, and correct the tag chip maker.
• Only for UHF
Cause:
Unsupported inlay (IC chip) is used when specifying the
MCS setting and encoding the SGTIN96.
Countermeasure:
Check the media, and change it to supported inlay.
• Only for UHF
Cause:
1. Tried to write to a write-locked tag.
2. Tried to write to a tag when the write power is low.
Countermeasure:
1. Use media that is not locked.
2. Adjust Write Power/Read Power.
• Only for ISO/IEC 15693, ISO/IEC 14443 Type A, FeliCa
Cause:
Incorrect tag type is specified.
Countermeasure:
Check the tag type, and specify the correct tag type.
• Only for ISO/IEC 15693, ISO/IEC 14443 Type A, FeliCa
Cause:
Failed to acquire the ID.
Countermeasure:
The radio wave condition needs to be improved. Increase
the Read Power level.