Honda CBF600SA Service Manual page 545

Table of Contents

Advertisement

Manuals by Motomatrix / www.motomatrix.co.uk / The Solution For Lost Motorcycle Coded Keys.
ELECTRIC STARTER
Install the starter motor into the crankcase.
NUT
STARTER MOTOR CABLE
Install the ground cable and mounting bolts, and
Route the wires
tighten the bolts securely.
properly (page 1-
Install the starter motor cable, then tighten the ter-
24).
RUBBER CAP
minal nut to the specified torque.
TORQUE: 10 N·m (1.0 kgf·m, 7 lbf·ft)
Install the rubber cap securely.
BOLTS
GROUND CABLE
Install a new O-ring into the groove of the water
WATER HOSE JOINT
BOLTS
hose joint.
Install the water hose joint to the cylinder block.
Tighten the bolts securely.
Install the following:
– thermostat (page 6-10)
– air cleaner housing (page 5-75)
Connect the battery negative cable.
O-RING
STARTER RELAY SWITCH
OPERATION INSPECTION
Remove the right side cover (page 2-5).
Shift the transmission into neutral.
Turn the ignition switch ON and engine stop switch
"
".
Press the starter switch button.
The coil is normal if the starter relay switch clicks.
If you don't hear the switch "click", inspect the relay
switch using the procedure below.
STARTER RELAY SWITCH
GROUND LINE INSPECTION
Disconnect the starter relay switch 4P connector.
4P CONNECTOR
Check for continuity between the Green/red wire
(ground line) and ground.
If there is continuity when the transmission is in
neutral or when the clutch is disengaged and the
side stand switch is retracted, the ground circuit is
normal (In neutral, there is a slight resistance due to
the diode).
19-15