FUEL SYSTEM (PGM-FI)
Install the mesh screen by aligning with the guides
of upper air cleaner housing.
Install the upper air cleaner housing onto the lower
housing.
Install and tighten the screws to the specified
torque.
TORQUE: 3.5 N·m (0.4 kgf·m, 2.6 lbf·ft)
Install a new right air cleaner duct packing into the
groove on the housing.
Install a new left air cleaner duct packing into the
groove on the housing.