5.4.8 Adjustment Procedures

Use this diagnostic procedure to control parameters of the mechanical and electromagnetic components
of the printer.
NOTE: Even though there are other routines displayed on the Control Panel when in the Adjustment
Procedures section of Diagnostics, only those routines that can be adjusted by the Service
Representative are listed in this manual.
1 Enter Diagnostic Mode (5.4).
2 Press [4] and [7] together, then release [7], while holding [4] until the UI counts to "3", then
release [4]. will allow you to enter the NVM diagnostics.
3 The printer is in NVM Diagnostics Mode.
4 Select an Adjustment Procedure from the table (Table 5.4.8a).
5 When you are finished, switch off the printer power to exit Diagnostic Mode.
Menu Selection
PAPER TRAIL EDGE
FORCED ERASE ADJ
PAPER LEAD EDGE
IMG ROS ADJ MBF
LASER SIDE REGI
ADJUSTMENT
DocuPrint N24, N32 and N40 Service Manual
Table 5.4.8a. Adjustment Procedures
Sub Menu
SELECT ALL TRAYS
SELECT TRAY 1
SELECT TRAY 2
SELECT TRAY 3
SELECT TRAY 4
SELECT TRAY 5
SELECT TRAY MBF
SELECT TRAY ENV
3/99
5-27
Min
Nominal
Max
0
12
71
35
50
99
01
50
99
01
50
99
01
50
99
01
50
99
01
50
99
01
50
99
01
50
99
01
50
99
General Procedures and Information
Step
Comment
1
Trail Edge Deletion
Gap for all Trays
step = 0.34 mm
1
Lead Edge ROS Turn
On for MBF Tray
step = 0.254 mm
35 = -3.81mm
50 = +/- 0.0mm
99 = +12.45mm
Side Edge Registra-
tion Adjustment -
Simplex Only
1
step =.258 mm
01 min = -12.64mm
50 nom = +/-0.0mm
99 max = +12.64mm
1
01 min = -12.64mm
50 nom = +/-0.0mm
99 max = +12.64mm
1
Same as Tray 1
1
Same as Tray 1
1
Same as Tray 1
1
Same as Tray 1
1
Same as Tray 1
1
Same as Tray 1