Sharp MX-C507P Service Manual page 334

Digital full color laser printer
Hide thumbs Also See for MX-C507P:
Table of Contents

Advertisement

5
Select OK.
6
Print a Quick test page to verify the change.
7
Repeat step 3 through to step 6 until the margins are properly adjusted.
8
Check for proper color alignment. See
Adjusting the color alignment
1
Enter the Diagnostics menu, and then navigate to:
Printer diagnostics & adjustments > Color alignment adjust
On the AA Adjustment row, press OK or touch Start.
Note: The Color alignment procedure is performed on the cyan, magenta, and yellow colors.
2
Enter the Diagnostics menu, and then navigate to:
Printer diagnostics & adjustments > Color alignment adjust > Cyan > Quick test
Check the alignment markings on the test page generated. Follow the instructions on the test page to correct
the color misalignment.
3
Enter the Diagnostics menu, and then navigate to:
Printer diagnostics & adjustments > Color alignment adjust > Yellow > Quick test
Check the alignment markings on the test page generated. Follow the instructions on the test page to correct
the color misalignment.
4
Enter the Diagnostics menu, and then navigate to:
Printer diagnostics & adjustments > Color alignment adjust > Magenta > Quick test
Check the alignment markings on the test page generated. Follow the instructions on the test page to correct
the color misalignment.
5
If color misalignment still occurs, then repeat step 1 through to step 4.
Removal procedures
Keep the following tips in mind as you replace parts:
Some removal procedures require removing cable ties. You must replace cable ties during reassembly to
avoid pinching wires, obstructing the paper path, or restricting mechanical movement.
Remove the toner cartridges, imaging unit, and media tray before removing other printer parts. The imaging
unit should be carefully set on a clean, smooth, and flat surface. It should also be protected from light while
out of the device.
Disconnect all external cables from the printer to prevent possible damage during service.
Unless otherwise stated, reinstall the parts in reverse order of removal.
When reinstalling a part held with several screws, start all screws before the final tightening.
"Adjusting the color alignment" on page
Parts removal
302
5028
302.

Advertisement

Table of Contents
loading

Table of Contents