Configuring the door interlock bypass jumpers
Note: The interlock bypass jumpers are only used with the following motors:
•
Motor (fuser)
•
Motor (K developer)
•
Motor (transfer module)
•
Motor (duplex/MPF)
The controller board has two door interlock bypass jumpers. These jumpers allow you to remove the motor
cover and open the toner door to see the motors in operation while being tested in diagnostics mode. The
JMTREN1 jumper connector allows you to bypass the interlock switches, and test the motor (fuser) and motor
(K developer/transfer module). The JMTREN2 jumper connector allows you to bypass the interlock switches,
and test the motor (duplex/MPF).
Note: If the jumpers are not set to the bypass position, and a motor test is performed while the toner door is
open, then a 1yy.80 error occurs.
•