Action
Step 6
Replace the controller board. See
page
393.
Does the problem remain?
150 and 160 errors
150 and 160 error messages
Error code Description
150.80
The motor (duplex/MPF) did not turn on.
160.80
The motor (duplex/MPF) did not turn on.
150.81
The motor (duplex/MPF) did not turn off.
160.81
The motor (duplex/MPF) did not turn off.
150.82
The motor (duplex/MPF) speed did not ramp up to
the required level.
160.82
The motor (duplex/MPF) speed did not ramp up to
the required level.
150.83
The motor (duplex/MPF) stalled.
160.83
The motor (duplex/MPF) stalled.
150.84
The motor (duplex/MPF) ran too slow.
160.84
The motor (duplex/MPF) ran too slow.
150.85
The motor (duplex/MPF) ran too fast.
150.86
The motor (duplex/MPF) did not run at the correct
timing.
160.86
The motor (duplex/MPF) did not run at the correct
timing.
"Controller board removal" on
Diagnostics and troubleshooting
215
Yes
Contact the next
level of support.
Action
See
"Motor (duplex/MPF) service check" on
page
216.
5028
No
The problem is
solved.