Sharp MX-C507P Service Manual page 317

Digital full color laser printer
Hide thumbs Also See for MX-C507P:
Table of Contents

Advertisement

Printhead diagnostics
This setting allows you to test the printhead.
1
Enter the Diagnostics menu, and then navigate to:
Printer diagnostics & adjustments > Printhead diagnostics
2
Select a test, and then touch Start.
Weather station
This setting lets you view the temperature of the weather station sensor.
1
Enter the Diagnostics menu, and then touch Printer diagnostics & adjustments.
2
From the Weather station section, touch Start.
Fuser temperature
This setting lets you view the fuser temperature.
1
Enter the Diagnostics menu, and then touch Printer diagnostics & adjustments.
2
From the Fuser temperature section, touch Start.
Additional input tray diagnostics
Sensor tests
1
Enter the Diagnostics menu, and then touch Additional input tray diagnostics.
2
From the Sensor tests section, touch Start.
A dialog listing the sensor tests appears.
3
Find, and then manually toggle the sensor.
Notes:
The sensor status on the screen toggles between 1 and 0 when the sensor is properly working.
If a sensor test fails, the test failure may not indicate a failed sensor. Further troubleshooting may be
required. Check the boards and cables for possible issues.
Motor tests
1
Enter the Diagnostics menu, and then navigate to:
Additional input tray diagnostics > Motor tests
2
Select a motor, and then touch Start.
Notes:
If the motor is activated, then it is properly working.
Some motors require automatic deactivation in order to avoid secondary issues such as possible
damage and contamination.
Service menus