Nortel 1000E Installation And Configuration Manual page 88

Nortel 1000e server: install guide
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Rack-mounting the components
Page 88 of 488
553-3041-210
Standard 4.00
WARNING
MAIN AC POWER DISCONNECT
A main AC power disconnect must be installed. The main
AC power disconnect must:
• disconnect power to the entire rack unit
• be readily accessible
• be labeled as controlling power to the entire unit, not
1
Attach the rack-mount brackets ("B" as shown in Figure 19 on
the equipment rack. Install the left and right side at an equal height. Use
standard length screws from the accessories pouch, and screw them into
the top and bottom drill holes of the bracket (see Figure 24 on
Figure 24
Installed rack-mount bracket
2
When both brackets are fixed in place:
a.
Align the rack-mount brackets on the Signaling Server with the slide
rail system on the rack posts.
b.
Slide the Signaling Server in place. Refer to Figure 25 on
September 2007
just to the Signaling Server(s)
page
83) to
page
88).
page
89.