Nortel 1000E Installation And Configuration Manual page 262

Nortel 1000e server: install guide
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Page 262 of 488
553-3041-210
Standard 4.00
Connecting a Terminal Server
5
Enable autoconnect for the port. Enter the command:
DEFINE PORT xx AUTOCONNECT ENABLED
Where:
xx = port number
6
Enable autodedicate for the port. Enter the command:
DEFINE PORT xx AUTODEDICATED ENABLED
Where:
xx = port number
7
Define a user name for the port. Enter the command:
DEFINE PORT xx USERNAME "ptyxx"
Where:
xx = port number
ptyxx = User Name is the pty port set during Call Server configuration
for rlogin connection. The pty port is set using LD 17. For example, in LD
17, configure TTY 2 as pty. The port # username on Terminal Server
becomes "pty2", not "PTY2" or "pty02".
Note 1: Ignore the following MRV information message during using
DEFINE command. "In-Reach -729- Parameter cannot be modified by a
set command". This is informational only that you must use DEFINE and
not the more general SET command. It is not an error.
Note 2: The quotation marks ("") are also required around "PTYxx"
8
Log out of the port. Enter the command:
LOGOUT PORT xx
Where:
xx = port number
September 2007