Configuring the MG 1000E ports

LD 97 – Configuring the MG 1000E ports (Part 1 of 2)
Prompt
Response
REQ
CHG
TYPE
SUPL
SUPL
0, 4, 8, -252
SLOT
<cr>
SUPT
IPMG
IPRO
xx.xx.xx.xx
Configuring the CS 1000E Call Server
The type of any Bandwidth Management Zone for MG 1000E with
conference resources configured must be shared.
Distortion in Music is expected when G.729AB codec is used. Hence the
Interzone and the Intrazone policies for an MG 1000E Bandwidth
Management Zone should have Best Quality to give preference to G711
codec to minimize of occurrence of music distortion.
Currently, the CS 1000E only supports Recorded Announcement
Broadcast and Music Broadcast.
Ensure that the bandwidth provisioned is adequate to provide the acceptable
blocking level of the resources in the MG 1000E. Refer to the
Communication Server 1000E: Planning and Engineering (553-3041-120)
for details.
IP addresses must be configured on the Call Server for each MG 1000E in the
system. Use LD 97 to configure the MG 1000E ports.
Comment
Change existing data
Superloop
Superloop number
Select default
MG 1000E
IP address of the first MG 1000E Uplink IP address; <cr> to
skip to IPR1 when configuring new superloop.
Communication Server 1000E
IMPORTANT!
Installation and Configuration
Page 213 of 488