Page 274 of 488
Figure 90
Maintenance to Signaling Server connection
PC Maintenance
Terminal
BayStack 470 SDI connection
Media Card SDI connection
553-3041-210
Standard 4.00
Configuring a terminal and SDI ports
2
The COM port on the PC Maintenance terminal should be set as follows:
•
Terminal type: VT100
•
Speed: 19200
•
Data bits: 8
•
Parity: none
•
Stop bits: 1
•
Flow control: none
After the installation, the Signaling Server maintenance port speed can be
changed. See Signaling Server: Installation and Configuration
(553-3001-212).
The SDI port on the Bay Stack 470 can be used for basic configuration and
maintenance. The SDI port is located on the faceplate. It is a DCE port with
a default speed of 9600 bps.
The SDI ports on a Media Card can be used for basic configuration or
maintenance. Figure 91 shows the maintenance port location on the Media
Card and the Shielded 50-pin to Serial/ELAN/TLAN adapter.
September 2007
serial