Nortel 1000E Installation And Configuration Manual page 140

Nortel 1000e server: install guide
Hide thumbs Also See for 1000E:
Table of Contents

Advertisement

Page 140 of 488
Reconfigure I/O ports and call registers
553-3041-210
Standard 4.00
Installing software on the CS 1000E
4
Print the customer data block in LD 21.
LD 21
REQ
TYPE
CUST
****
Procedure 24
Reconfiguring I/O ports and call registers
1
Evaluate the number of call registers and 500 telephone buffers that are
configured for the system (suggested minimum values are 4500 and 1000
respectively). If changes are required, reconfigure the values in LD 17:
LD 17
500B 1000
NCR 20000
****
2
Print the Configuration Record to confirm the changes made in Step 1:
LD 22
REQ PRT
TYPE CFN
****
Procedure 25
Switching call processing to the Call Server
1
Plug the Call Server port labeled Lan 1 into the ELAN subnet.
2
Initialize (using the init button) the CP PIV card in the Core.
September 2007
Load program
PRT
CDB
xx
Exit program
Load program
Use 1000 as a minimum value
Use 20000 as a minimum value
Exit program
Load program
Set the print option
Print the configuration
Exit program
End of Procedure